Handleiding
Je bekijkt pagina 53 van 72

7 | Maintenance and service
User reference guide
53
FTXJ-A(W)(S)(B)
Daikin room air conditioner
4P518786-9J – 2022.05
7 Maintenance and service
In this chapter
7.1 Overview: Maintenance and service...................................................................................................................................... 53
7.2 To clean the indoor unit and wireless remote control .......................................................................................................... 54
7.3 To clean the front panel ......................................................................................................................................................... 55
7.4 To open the front panel ......................................................................................................................................................... 55
7.5 About the air filters................................................................................................................................................................. 56
7.6 To clean the air filters............................................................................................................................................................. 56
7.7 To clean the titanium apatite deodorising filter and the silver particle filter (Ag-ion filter) ................................................ 57
7.8 To replace the titanium apatite deodorising filter and the silver particle filter (Ag-ion filter)............................................. 58
7.9 To close the front panel.......................................................................................................................................................... 58
7.10 To remove the front panel ..................................................................................................................................................... 59
7.11 To take following items into account before a long idle period............................................................................................ 60
7.1 Overview: Maintenance and service
The installer has to perform a yearly maintenance.
About the refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent gases into the
atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
NOTICE
Applicable legislation on fluorinated greenhouse gases requires that the refrigerant
charge of the unit is indicated both in weight and CO
2
equivalent.
Formula to calculate the quantity in CO
2
equivalent tonnes: GWP value of the
refrigerant × total refrigerant charge [in kg] / 1000
Please contact your installer for more information.
WARNING
▪ The refrigerant inside the unit is mildly flammable, but normally does NOT leak. If
the refrigerant leaks in the room and comes in contact with fire from a burner, a
heater, or a cooker, this may result in fire, or the formation of a harmful gas.
▪ Turn OFF any combustible heating devices, ventilate the room, and contact the
dealer where you purchased the unit.
▪ Do NOT use the unit until a service person confirms that the part from which the
refrigerant leaked has been repaired.
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts.
▪ Do NOT use cleaning materials or means to accelerate the defrosting process
other than those recommended by the manufacturer.
▪ Be aware that the refrigerant inside the system is odourless.
Bekijk gratis de handleiding van Daikin FTXJ35A2V1BW, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Daikin |
Model | FTXJ35A2V1BW |
Categorie | Airco |
Taal | Nederlands |
Grootte | 9549 MB |