Handleiding
Je bekijkt pagina 27 van 78

D-EOMAC01905-23_01EN- 27/78
Parameter
Range
Max Reset (MR)
0.0°C 10.0°C
Start Reset DT
10.0°C 29.4°C
Max Reset OAT
(MROAT)
10.0°C 29.4°C
Start Reset OAT
(SROAT)
10.0°C 29.4°C
4.10.4 Softload
Soft Loading is a configurable function used to ramp up the unit capacity over a given time period, usually used to
influence building electrical demand by gradually loading the unit. To enable Softload, go to the page:
Main Menu→View / Set Unit→Power Conservation→ Softload
Once the Softload Ramp and the Starting Cap have been set, if the Softload is enabled, the machine is forced to
ramp up the capacity based on settings. It works when the machine is starting from 0%, reaching the maximum load with
the speed settable by the customer.
If the Softload is enabled when the machine is already running, if the Starting Cap>Actual Capacity, the
Softload will ramp up the Capacity with the speed set by the customer.
Parameter
Description
Softload
Enable
Enables soft loading
Softload
Ramp
Duration of the soft load
ramp
Starting
Cap
Begin capacity limit. Unit
will increase capacity
from this value to 100%
over the time specified
by the Softload Ramp
setpoint.
0
SRT
Evap T
AS
LWT SP
MR
LWT SP + MR
Bekijk gratis de handleiding van Daikin EWAH920TZSLB2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Daikin |
Model | EWAH920TZSLB2 |
Categorie | Airco |
Taal | Nederlands |
Grootte | 11657 MB |