Daikin ETVZ16S18EA6V7 handleiding

64 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 47 van 64
5 | Operation
User reference guide
47
ETVZ16S18+23E
Daikin Altherma 3 H HT F
4P644741-1A – 2022.03
Go to setpoint mode … Set the setpoint mode to …
Main zone – Heating
[2.4] Main zone > Setpoint mode WD heating, fixed cooling OR
Weather dependent
Main zone – Cooling
[2.4] Main zone > Setpoint mode Weather dependent
Additional zone – Heating
[3.4] Additional zone > Setpoint
mode
WD heating, fixed cooling OR
Weather dependent
Additional zone – Cooling
[3.4] Additional zone > Setpoint
mode
Weather dependent
Tank
[5.B] Tank > Setpoint mode Restriction: Only available to installers.
Weather dependent
To change the type of weather-dependent curve
To change the type for all zones (main + additional) and for the tank, go to [2.E]
Main zone > WD curve type.
Viewing which type is selected is also possible via:
[3.C] Additional zone > WD curve type
[5.E] Tank > WD curve type
Restriction: Only available to installers.
To change the weather-dependent curve
Zone Go to …
Main zone – Heating [2.5] Main zone > Heating WD
curve
Main zone – Cooling [2.6] Main zone > Cooling WD
curve
Additional zone – Heating [3.5] Additional zone > Heating
WD curve
Additional zone – Cooling [3.6] Additional zone > Cooling
WD curve
Tank Restriction: Only available to installers.
[5.C] Tank > WD curve
INFORMATION
Maximum and minimum setpoints
You cannot configure the curve with temperatures that are higher or lower than the
set maximum and minimum setpoints for that zone or for the tank. When the
maximum or minimum setpoint is reached, the curve flattens out.