Daikin ETBX16DF9W handleiding

264 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 64 van 264
6 | Unit installation
Installer reference guide
64
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
1
1
2
33
1
1
2
3
4
6.2.3 To remove the transportation stay
NOTICE
If the unit is operated with the transportation stay attached, abnormal vibration or
noise may be generated.
The transportation stays (2×) protect the unit during transport. During installation
they must be removed.
a
a Transportation stays (2×)
1 Open the switch box cover. See "6.2.2To open the outdoor unit"[463].
2 Remove the screws (4×) from the transportation stays, and dispose of them.
3 Remove the transportation stays (2×), and dispose of them.
6.2.4 To close the outdoor unit
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1N•m.

Bekijk gratis de handleiding van Daikin ETBX16DF9W, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDaikin
ModelETBX16DF9W
CategorieNiet gecategoriseerd
TaalNederlands
Grootte40307 MB