8 | Electrical installation
Installer reference guide
112
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
CB
5 63 4
X5M
X5M
3 Fix the cable with cable ties to the cable tie mountings.
8.3.5 To connect the domestic hot water pump
Wires: (2+GND)×0.75mm²
DHW pump output. Maximum load: 2A (inrush), 230VAC, 1A
(continuous)
[9.2.2] DHW pump
[9.2.3] DHW pump schedule
1 Open the following (see "6.2.5To open the indoor unit"[465]):
1 Front panel
1
2
3
2 Switch box cover
3 Switch box
2 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
B
C
A
A
1~
M
M2P