Daikin ETBH16DF6V handleiding

264 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 98 van 264
8 | Electrical installation
Installer reference guide
98
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
L1 L2 L3 N PE
b
a
L1
L2
L3
N
3N~,
50 Hz,
400 V AC
b
a
Q1DI
L1
L2
L3
N
F1B
1
3
5
7
2
4
6
8
IIII
BRN
GRY
BLK
BLU
YLW/GRN
a Factory-mounted power supply cable
b Field wiring
F1B Overcurrent fuse (field supply). Recommended fuse: 4 pole, 16A or 20A fuse, C curve.
Q1DI Earth leakage circuit breaker (30mA)(field supply)
2 Interconnection cable (indoor↔outdoor):
Route the cable through the frame.
Connect the wires to the terminal block (make sure the numbers match with
the numbers on the indoor unit) and the earth screw.
Fix the cable with a cable tie.
Wires: (3+GND)×1.5mm²