6 | Unit installation
Installer reference guide
64
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
1
1
2
33
1
1
2
3
4
3×
6.2.3 To remove the transportation stay
NOTICE
If the unit is operated with the transportation stay attached, abnormal vibration or
noise may be generated.
The transportation stays (2×) protect the unit during transport. During installation
they must be removed.
a
a Transportation stays (2×)
1 Open the switch box cover. See "6.2.2To open the outdoor unit"[463].
2 Remove the screws (4×) from the transportation stays, and dispose of them.
3 Remove the transportation stays (2×), and dispose of them.
6.2.4 To close the outdoor unit
NOTICE
When closing the outdoor unit cover, make sure that the tightening torque does NOT
exceed 4.1N•m.