5 | Application guidelines
Installer reference guide
35
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
room thermostat), while the other rooms are controlled by so-called thermostatic
valves, which open or close depending on the room temperature.
Setup
T
B C
a
A
A Main leaving water temperature zone
B Room 1
C Room 2
a Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat)
For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[494]
- "8.3Connections to the indoor unit"[4101]
The underfloor heating of the main room is connected as follows:
- Warm water → Indoor unit
- Cold water → Outdoor unit
The room temperature of the main room is controlled by the dedicated Human
Comfort Interface (BRC1HHDA used as room thermostat).
A thermostatic valve is installed before the underfloor heating in each of the
other rooms.
INFORMATION
Mind situations where the main room can be heated by another heating source.
Example: Fireplaces.
Configuration
Setting Value
Unit temperature control:
#: [2.9]
Code: [C-07]
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the dedicated Human
Comfort Interface.
Number of water temperature zones:
#: [4.4]
Code: [7-02]
0 (Single zone): Main
Benefits
Easy. Same installation as for one room, but with thermostatic valves.