Daikin ETBH16DF6V handleiding
Handleiding
Je bekijkt pagina 30 van 264

5 | Application guidelines
Installer reference guide
30
EPRA14~18DAV3+W1 + ETBH/X16DA6V+9W
Daikin Altherma 3 H HT W
4P587501-1A – 2020.01
5.2.1 Single room
Underfloor heating or radiators – Wired room thermostat
Setup
A
B
a
A Main leaving water temperature zone
B One single room
a Dedicated Human Comfort Interface (BRC1HHDA used as room thermostat)
▪ For more information about connecting the electrical wiring to the unit, see:
- "8.2Connections to the outdoor unit"[494]
- "8.3Connections to the indoor unit"[4101]
▪ The underfloor heating or radiators are connected as follows:
- Warm water → Indoor unit
- Cold water → Outdoor unit
▪ The room temperature is controlled by the dedicated Human Comfort Interface
(BRC1HHDA used as room thermostat).
Configuration
Setting Value
Unit temperature control:
▪ #: [2.9]
▪ Code: [C-07]
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the dedicated Human
Comfort Interface.
Number of water temperature zones:
▪ #: [4.4]
▪ Code: [7-02]
0 (Single zone): Main
Benefits
▪ Highest comfort and efficiency. The smart room thermostat functionality can
decrease or increase the desired leaving water temperature based on the actual
room temperature (modulation). This results in:
- Stable room temperature matching the desired temperature (higher comfort)
- Less ON/OFF cycles (more quiet, higher comfort and higher efficiency)
- Lowest possible leaving water temperature (higher efficiency)
Bekijk gratis de handleiding van Daikin ETBH16DF6V, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Daikin |
| Model | ETBH16DF6V |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 40307 MB |







