Installation manual
5
ERSQ+ERRQ011~016AAV1+Y1
Outdoor unit for air to water heat pump
4PW49635-1C
■ For ERRQ only. Follow the procedure as described below for
modifying the position of the air thermistor (R1T). The thermistor
fixture is delivered in the accessory bag.
4.2. Precautions on installation
■ Check the strength and level of the installation ground so that
the unit will not cause any operating vibration or noise after
installation.
■ In accordance with the foundation drawing in the figure, fix the
unit securely by means of the foundation bolts. (Prepare 4 sets
of M12 foundation bolts, nuts and washers each which are
available on the market.)
■ It is best to screw in the foundation bolts until their length are
20 mm from the foundation surface.
NOTE
Spare thermistor fixing plate is delivered in the
accessory bag.
2
1
3
4
5
6
8
7
9
10
A Discharge side
B Bottom view (mm)
C Drain hole
11
20
140
117
219
289
350
(345-355)
47
140620
614
423
A
B
C