Daikin EKRRVATR2BA handleiding
Handleiding
Je bekijkt pagina 17 van 52

2 | Applications
Application Guide
17
EKRACP* + EKRCTR* + EKRMIB* + EKRRVA* + EKRSEN* + EKRSIB* +
EKRUFH*
Daikin Home Controls
4P701747-1A – 2023.10
k Underfloor heating
Configuration
The configuration is done by adding the Daikin Altherma unit in the ONECTA app.
For more information on how to do so, see the manuals of the DHC Access Point.
After setting the presence of the dehumidifier and adjusting the installer mode
settings on the Daikin Altherma unit, the ONECTA app will automatically take care
of all configurations of the DHC accessories.
Configuration of the dehumidifier
These settings ONLY apply to a dehumidifier of type RE*. No configuration is
required for a dehumidifier of type RS*. For more detailed information on
configuration, see the manual of the respective dehumidifier.
Description Value
17-IC Treatment
input
Invert logic Used to switch on/off
heating/cooling/
dehumidification functions.
No
18-IC Season input Used to set the season
(summer/winter).
No
11-14 Dew point
alarm
Triggered when dew point
alarm is reached.
No
2.2 Bizone
2.2.1 Bizone heating only
NOTICE
The MMI settings MUST be adjusted first. See "5User interface settings"[422].
For this application, there MUST be one DHC Room Thermostat — 1 or 2 present
per room you wish to control. If there's a DHC Radiator Thermostat in the room,
the DHC Room Thermostat — 1 or 2 is optional.
a
b
c
d
h
j j j
g
i
ff f
e
a Daikin Altherma
b Underfloor heating demand
c Radiator demand
d DHC Basic IO Box
e DHC Access Point
f DHC Room Thermostat — 1 or 2
Bekijk gratis de handleiding van Daikin EKRRVATR2BA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.