4 Operation
User reference guide
11
EBLQ05+07CAV3 + EDLQ05+07CAV3 + EKCB07CAV3 +
EK2CB07CAV3 + EKMBUHCA3V3 + EKMBUHCA9W1
Daikin Altherma low temperature monobloc
4P405545-1 – 2015.03
You can… Location
Read out the desired reheat temperature. DHWtank
temperature
home page
Adjust the reheat temperature.
Condition: is displayed on the DHWtank
temperature home page.
Activate the DHWtank booster mode.
Program a booster heater allowance schedule
to restrict when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
Menu structure
(Only for field supplied domestic hot water
pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.
See also:
▪ "4.5.5Using the DHWtank temperature home page"on page12
▪ "4.5.6Using the DHWtank booster mode"on page12
▪ "4.7Preset values and schedules"on page15
4.5.3 Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because the space heating demand is
lower.
Example:
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
5
T
t
T
t
DHWtank temperature
t Time
▪ Initially, the DHW tank temperature is the same as the
temperature of the domestic water entering the DHW tank
(example: 15°C).
▪ At 00:00 the DHWtank is programmed to heat up the water to a
preset value (example: Storage comfort = 60°C).
▪ During the morning, you consume hot water and the DHW tank
temperature decreases.
▪ At 14:00 the DHWtank is programmed to heat up the water to a
preset value (example: Storage eco = 50°C). Hot water is
available again.
▪ During the afternoon and evening, you consume hot water again
and the DHWtank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
In scheduled mode, you can do the following:
You can… Location
Read out the active or next scheduled desired
temperature.
DHWtank
temperature
home page
Overrule the active or next scheduled desired
temperature.
Condition: is displayed on the DHWtank
temperature home page.
Activate the DHWtank booster mode.
Select a DHWtank temperature schedule. Menu structure
Program a DHWtank temperature schedule.
Define preset values that are used by the
DHWtank temperature schedule.
Program a booster heater allowance schedule
to restrict when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
(Only for field supplied domestic hot water
pump for secondary return)
Program a domestic hot water pump schedule
to determine when to turn ON and OFF the pump.
When turned ON, the pump runs and makes sure
hot water is instantly available at the tap. To save
energy, only turn ON the pump during periods of
the day when instant hot water is necessary.
See also:
▪ "4.5.5Using the DHWtank temperature home page"on page12
▪ "4.5.6Using the DHWtank booster mode"on page12
▪ "4.7Preset values and schedules"on page15
4.5.4 Scheduled + reheat mode
In scheduled + reheat mode ( ), the domestic hot water control is
the same as in scheduled mode. However, when the DHW tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis value; example: 35°C), the DHW tank heats up until it
reaches the reheat set point (example: 45°C). This ensures that a
minimum amount of hot water is available at all times.
Example:
t
T
t
60°C
00:00 07:00
50°C
45°C
15°C
14:00 21:00
35°C
1
2
4
5
3
T
t
DHWtank temperature
t Time
60°C Storage comfort
50°C Storage eco
45°C Reheat
35°C Reheat tank temperature–hysteresis value
In scheduled + reheat mode, you can do the following:
You can… Location
Do the same things as in scheduled mode. —
Adjust the preset value (Reheat). Menu structure