4 Operation
User reference guide
9
EHBH04~16CBV + EHVH04~16S18+26CBV
Daikin Altherma – Low temperature split
4P449972-1 – 2016.06
Result: For the next 2 hours, the room will NOT be heated to the
scheduled 20°C, but to the preset value (Eco = 18°C). After the
2hours, the room will heat up again to the scheduled 20°C.
Advantage:
You save energy because you do NOT heat the room unnecessary,
and by the time you come home the room is warm again.
4.4.6 Room thermostat control - Using the
leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water temperature than radiators and heat pump
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
Typical leaving water temperature home pages
Main zone:
User profile = Basic User profile = Detailed
15:20
35°C
LWT main
Desired temperature
Mon
15:20
35°C
17:30
Mon
Mon
Desired temperature
LWT main
Additional zone:
User profile = Basic User profile = Detailed
15:20
45°C
Desired temperature
LWT add
Mon
15:20
45°C
17:30
Mon
Mon
LWT add
Desired temperature
To read out the desired leaving water temperature
(main + additional)
Go to the leaving water temperature home page (LWT main or LWT
add).
To adjust/overrule the leaving water temperature
(NOT linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to
the room temperature setpoint, see "4.4.3 Determining
which temperature control you are using"on page6.
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT
main).
2 Press
or to adjust. Example:
35°C 37°C
INFORMATION
In case of weather dependency, an offset value can be
modified.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be
modified.
To adjust/overrule the leaving water temperature
(linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to
the room temperature setpoint, see "4.4.3 Determining
which temperature control you are using"on page6.
To set leaving water temperature preset values (main)
INFORMATION
You cannot adjust/overrule the leaving water temperature
(main) for room thermostat control with linked leaving
water temperatures. However if necessary, you can adjust
the desired leaving water temperature (main) by adjusting
preset values.
INFORMATION
Adjusting the leaving water temperature is permanent
unless the leaving water temperature is according to a
schedule. In that case the overruling is valid until the next
scheduled action.
1 Go to [7.4.2]:
> User settings > Preset values > LWT main.
2 Set the Preset values according to following graph.
Example: Room thermostat comfort temperature will correspond
with leaving water comfort temperature.
T
l
T
r
T
r
: Room temperature
T
l
: Leaving water temperature
3 Press
or to adjust/overrule.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or to adjust. Example:
45°C 47°C
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.4.7 Leaving water temperature control -
About leaving water temperature control
Leaving water temperature control means that you only control the
leaving water temperature. To control the leaving water temperature,
you can do the following: