4 | Operation
User reference guide
33
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1A – 2021.10
Current time = 10:30
Next scheduled action of the DHW tank = Heat up to the preset value (Eco;
example: 55°C and sufficient for 2 persons) at 14:00
This evening you need hot water for 3persons
Then you can do the following:
1 Go to the DHWtank temperature home page (Tank).
2 Overrule the next scheduled action by changing from 55°C to 60°C.
Advantages:
You will have sufficient hot water (=comfortable).
You do NOT have to change the schedule (=easy).
You do NOT have to activate the DHWtank booster mode (=energy saving).
4.5.6 Using the DHWtank booster mode
About the DHWtank booster mode
You can use the DHW tank booster mode to immediately start heating up the
water to the preset value (Storage comfort). However, this consumes extra
energy.
To check if the DHWtank booster mode is active
1 Go to the DHWtank temperature home page (Tank).
2 Check the following:
In user profile = Basic: If is displayed, the DHW tank booster mode is
active.
In user profile = Detailed: If is selected, the DHWtank booster mode is
active.
To activate the DHWtank booster mode (user profile = Basic)
1 Go to the DHWtank temperature home page (Tank).
2 Press for more than 5seconds.
To activate the DHWtank booster mode (user profile = Detailed)
1 Go to the DHWtank temperature home page (Tank).
2 Press to select .
Usage example: You immediately need more hot water
If you are in the following situation:
You already consumed most of your hot water.
You cannot wait for the next scheduled action to heat up the DHWtank.
Then you can activate the DHWtank booster mode.
Advantage: The DHWtank immediately starts heating up the water to the preset
value (Storage comfort).
INFORMATION
When the DHW tank booster mode is active, the risk of space heating/cooling and
capacity shortage comfort problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling interruptions will happen.