Daikin EHFZ03S18DJ3V handleiding
Handleiding
Je bekijkt pagina 29 van 60

4 | Operation
User reference guide
29
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1A – 2021.10
4.5.1 About domestic hot water control
Depending on the DHWtank mode (installer setting), you use a different domestic
hot water control:
▪ Reheat mode
▪ Scheduled mode
▪ Scheduled + reheat mode
To determine which DHWtank mode you are using (method1)
Check the installer settings table filled in by the installer.
To determine which DHWtank mode you are using (method 2)
Prerequisite: User profile = Detailed.
1 Go to the DHWtank temperature home page (Tank).
2 Check which icons are displayed:
If… is displayed Then the DHWtank mode =…
Reheat mode
Scheduled mode
Scheduled + reheat mode
4.5.2 Reheat mode
In reheat mode ( ),the DHWtank continuously heats up to the temperature shown
on the DHWtank temperature home page (example: 50°C).
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
T
t
T
t
Domestic hot water tank temperature
t Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort
problem is significant. In case of frequent reheat operation, space heating/cooling
function is regularly interrupted.
In reheat mode, you can do the following:
You can… Location
Read out the desired reheat temperature. DHWtank
temperature home
page
Adjust the reheat temperature.
Condition: is displayed on the DHWtank temperature
home page.
Activate the DHWtank booster mode.