4 | Operation
User reference guide
29
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1A – 2021.10
4.5.1 About domestic hot water control
Depending on the DHWtank mode (installer setting), you use a different domestic
hot water control:
Reheat mode
Scheduled mode
Scheduled + reheat mode
To determine which DHWtank mode you are using (method1)
Check the installer settings table filled in by the installer.
To determine which DHWtank mode you are using (method 2)
Prerequisite: User profile = Detailed.
1 Go to the DHWtank temperature home page (Tank).
2 Check which icons are displayed:
If… is displayed Then the DHWtank mode =…
Reheat mode
Scheduled mode
Scheduled + reheat mode
4.5.2 Reheat mode
In reheat mode ( ),the DHWtank continuously heats up to the temperature shown
on the DHWtank temperature home page (example: 50°C).
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
T
t
T
t
Domestic hot water tank temperature
t Time
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort
problem is significant. In case of frequent reheat operation, space heating/cooling
function is regularly interrupted.
In reheat mode, you can do the following:
You can… Location
Read out the desired reheat temperature. DHWtank
temperature home
page
Adjust the reheat temperature.
Condition: is displayed on the DHWtank temperature
home page.
Activate the DHWtank booster mode.