4 | Operation
User reference guide
19
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1A – 2021.10
Typical automatic changeover restrictions
When Restriction
During cold season.
Example: October, November, December, January,
February and March.
Heating only
During warm season.
Example: June, July and August.
Cooling only
In-between.
Example: April, May and September.
Heating/Cooling
4.4.3 Determining which temperature control you are using
To determine which temperature control you are using (method1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using (method2)
If you have 2 user interfaces, perform the following procedure on the user
interface at the indoor unit.
Prerequisite: You switched the permission level to Advanced end user.
1 Press multiple times to switch between home pages, and check if the
additional leaving water temperature home page (LWT add) is available:
If … Then you have…
Available A main zone and an additional zone
NOT available Only a main zone
Typical additional leaving water temperature home page:
User profile = Basic User profile = Detailed
15:20
45°C
Desired temperature
LWT add
Mon
15:20
45°C
17:30
Mon
Mon
LWT add
Desired temperature
2 Check the following:
If… Then the temperature control is…
Main zone Additional zone (if
any)
Room temperature is listed
under:
[6.1]: > Information >
Sensor information
Room thermostat
control.
Go to next step to
check if leaving water
setpoint and room
temperature setpoint
are linked.
External room
thermostat control.