4 | Operation
User reference guide
13
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596825-1A – 2021.10
Icon Description
The preset value (Comfort or Eco) or scheduled value is
temporarily overruled.
The DHWtank booster mode is active or ready to be activated.
Quiet mode is active.
Holiday mode is active or ready to be activated.
Button lock mode and/or function lock mode is active.
An external heat source is active. Example: Gas burner.
The disinfection mode is active.
A malfunction occurred. Press to display more information
about the malfunction.
Weather-dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
4.1.3 User Permission level
The amount of information you can read out and edit in the menu structure
depends on your user permission level:
▪ End user: Default user mode.
▪ Adv. end user: As an advanced end user, you can read out and edit more
information.
To set the user permission level to Advanced end user
1 Go to the main menu or any of its submenus: .
2 Press for more than 4seconds.
Result: Your user permission level is now Adv. end user. The user interface
displays additional information and a "+" is added to the menu title. The user
permission level stays in Adv. end user until manually set otherwise.
To set the user permission level to End user
1 Press for more than 4 seconds.
Result: Your user permission level is now End user. The user interface displays
the default home page.