Daikin EBSX11P50DG handleiding
Handleiding
Je bekijkt pagina 24 van 316

4 | About the box
Installer reference guide
24
ERLA11~16D + EBSH/X(B)11+16P30+50D
Daikin Altherma 3 R ECH₂O
4P663482-1C – 2023.05
▪ Put the sling through the unit's left feet.
▪ Carry the unit using the sling (left) and the unit's handles (right), and put it
onto the installation structure.
▪ Remove the sling, and dispose of it.
±101
kg
4.1.2 To remove the transportation stay
NOTICE
If the unit is operated with the transportation stay attached, abnormal vibration or
noise may be generated.
The transportation stay protects the unit during transport. During installation it
must be removed.
Prerequisite: Open the service cover. See "7.2.2To open the outdoor unit"[482].
(10.1 N·m)
4
1
a
c
b
2
3
a Nut
b Transportation stay
c Spacer
1 Remove the nut (a) of the compressor mounting bolt.
2 Remove and discard the transportation stay (b).