3 | Specific installer safety instructions
Installer reference guide
16
ERLA11~16D + EBSH/X(B)11+16P30+50D
Daikin Altherma 3 R ECH₂O
4P663482-1C – 2023.05
3 Specific installer safety instructions
Always observe the following safety instructions and regulations.
Handling the unit (see
"4.1.1To handle, unpack and remove accessories –
Outdoor unit"[
4
22]
)
CAUTION
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit.
Application guidelines (see
"6Application guidelines"[
4
33]
)
CAUTION
If there is more than one leaving water zone, ALWAYS install a mixing valve station in
the main zone to decrease (in heating)/increase (in cooling) the leaving water
temperature when the additional zone has demand.
CAUTION
The solar panels MUST be installed higher than the indoor unit. A downward slope
with minimum gradient of the solar piping MUST be guaranteed. This is to allow the
solar system to completely drain and thereby to avoid frost damages.
Installation site (see
"7.1Preparing the installation site"[
4
67]
)
WARNING
Follow the service space dimensions in this manual for correct installation of the unit.
Outdoor unit: See "17.1Service space: Outdoor unit"[4288].
Indoor unit: See "7.1.3Installation site requirements of the indoor unit"[470].
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
WARNING
DO NOT reuse refrigerant piping that has been used with any other refrigerant.
Replace the refrigerant pipes or clean thoroughly.
CAUTION
Install the indoor unit at a minimum distance of 1m from other heat sources (>80°C)
(e.g. electrical heater, oil heater, chimney) and combustible materials. Otherwise the
unit may be damaged or in extreme cases catch fire.
Special requirements for R32 (see
"7.1.1Installation site requirements of the
outdoor unit"[
4
67]
)
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use means to accelerate the defrosting process or to clean the
equipment, other than those recommended by the manufacturer.
Be aware that R32 refrigerant does NOT contain an odour.

Bekijk gratis de handleiding van Daikin EBSX11P50DG, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkDaikin
ModelEBSX11P50DG
CategorieNiet gecategoriseerd
TaalNederlands
Grootte49782 MB