Table of contents
Technician - Installation ............................16
Technician - Electrical connections...................16
Define application...................................16
System schemes ...................................17
Key ...................................................17
System 1 (1 collector, 1 buffer storage tank) ....................17
System 2 (1 solid fuel boiler, 1 storage tank or 1 solid fuel boiler, 2
storage tanks with switch-over valve) .........................18
System 3 (1 collector, 1 storage tank, 1 solid fuel boiler) ...........19
System 4 (2 collectors, 1 storage tank, 2 collector pumps) .........19
System 5 (1 collector, 2 storage tanks, 1 switch-over valve) ........20
System 6 (1 collector, 2 storage tanks, 2 charge pumps) ..........21
System 7 (1 collector, 1 storage tank or 2 storage tanks) ..........22
System 8 (1 collector, 1 storage tank, return temperature increase) . .23
System 9 (1 solid fuel boiler, 1 storage tank, return temperature
increase with mixer).......................................23
System 10 (1 collector, 2 storage tanks, refeeding pump) ..........24
System 11 (1 collector, 1 storage tank, 2 feeding areas) . . . . . . . . . . .24
System 12 (1 collector, 1 storage tank, 3 feeding areas) . . . . . . . . . . .25
System 13 (1 collector, 1 storage tank, drain-back system).........26
Special functions ...................................28
Circulation pump .........................................28
Reheating ..............................................28
Return temperature increase ................................29
Connection diagram controller in socket .................30
Connection RDS2/EKSRDS2A ..............................31
Technician – Settings...............................32
Assistant (system installation) ..........................32
Parameters .......................................33
Change Code no. ........................................33
Set parameters ..........................................33
Relaistest (Relay test) ................................34
Reset ............................................34
Technician – Parameters............................36
List of parameters P21 to P110 . . . . . . . . . . . . . . . . . . . . . . . . 36
Explanation of the parameters .........................37
P21 Code No. ...........................................37
P22 Select system........................................37
P23 Speed level value .....................................37
P24 Op. mode speed cntrl .................................37
P25 Speed level (Manual) ..................................38
P26 Min. Speed level (Auto).................................38
P27 Max. Speed level (Auto) ................................38
P28 Temperature difference for 100% control ...................38
P30 Switch-on threshold 1 .................................38
P31 Switch-off threshold 1 .................................38
P32 Switch-on threshold 2,
P33 Switch-off threshold 2 .................................38
P34 Hysteresis reheating...................................39
P40 Collector enable temperature,
P41 Collector disable temperature ...........................39
P42 Maximum collector temperature..........................39
P43 Enable temperature 2nd heat gen. (solid fuel boiler) ...........39
P44 Maximum boiler temperature (solid fuel boiler) ...............40
P45 Collector safety temperature ............................40
P46 Storage tank recooling switching threshold .................40
P47 Reheating set temperature..............................40
P50 Maximum storage tank temperature, tank 1.................40
P51 Maximum storage tank temperature, tank 2.................41
P52 Tolerance during solar production ........................41
P53 Hot water short heating ................................41
P54 Function A2 and/or A3 .................................42
P55 Circulation pump on time ...............................42
P56 Circulation pump blocking ..............................42
P57 Minimum return flow temperature.........................42
P58 Mixer dynamic Open,
P59 Mixer dynamic Close ..................................42
P60 Kick duration ........................................43
P61 Kick pause ..........................................43