User’s Manual EM11A015H
intelligent Touch Manager
331
Setting location Number of settings
Automatic
Control function
Schedule function Number of schedule programs Up to 100
Number of schedule patterns Weekly: 7 patterns
Special day: 5 patterns
Number of events Up to 20 per schedule
Yearly calendar Calendar view 1 year
Maximum number of calendars that
can be registered
40 affairs
Interlocking Control function Number of interlocking programs Up to 500
Number of management points that
can be used as input
Up to 50
Number of events for Output1
Up to 25 management points, area: 1 area
(management points cannot be registered)
Number of events for Output2
Up to 25 management points, area: 1 area
(management points cannot be registered)
Emergency Stop function Number of emergency stop
programs
Up to 32
(Including the Default program)
Number of management points that
can be registered in one group
Up to 650
Number of management points that
can be used in an emergency stop
signal
Up to 6
Auto Changeover function Number of groups that can be
created
Up to 512 groups
Number of management points that
can be registered in one group
Up to 64
Temperature Limit function Number of groups that can be
created
Up to 8 groups
Number of management points that
can be registered in one group
Up to 512
Sliding Temperature function Number of groups that can be
created
Up to 8 groups
Number of management points that
can be registered in one group
Up to 512
Number of Ai management points
that can be registered in one group
Up to 1
HMO function Number of management points that
can be controlled with HMO
Up to 512
Timer Extension function Timer Extension times Selectable from 30 Min, 60 Min,
90 Min, 120 Min, 150 Min, 180 Min
Automatic
Control function
Setback function Relative Setup Setpoint
Selectable from 1°C to 7°C for both
Setback High and Setback Low
Relative Setback Setpoint
Recovery setpoint Selectable in the range
Cool Recovery Temperature: 1°C to 6°C
Heat Recovery Temperature: 1°C to 6°C