5 | Installation
Installer reference guide
22
BRP069A61+BRP069A62
Daikin Altherma LAN adapter
4P464229-1E – 2023.11
5.3 Connecting the electrical wiring
5.3.1 About connecting the electrical wiring
Typical workflow
Connecting the electrical wiring typically consists of the following stages:
System layout Typical workflow
App control (only) ▪ Connecting the adapter to the indoor
unit (P1/P2).
▪ Connecting the adapter to a router.
Smart Grid application (only) ▪ Connecting the adapter to the indoor
unit (P1/P2).
▪ Connecting the adapter to a solar
inverter/energy management system.
▪ Connecting the adapter to an
electricity meter (optional).
For more information about the Smart
Grid application, see "7Smart Grid
application"[437].
App control + Smart Grid application ▪ Connecting the adapter to the indoor
unit (P1/P2).
▪ Connecting the adapter to a router.
▪ Connecting the adapter to a solar
inverter/energy management system,
if required by the Smart Grid
application.
▪ Connecting the adapter to an
electricity meter, if required by the
Smart Grid application (optional).
For more information about the Smart
Grid application, see "7Smart Grid
application"[437].
5.3.2 Precautions when connecting the electrical wiring
INFORMATION
Also read the precautions and requirements in the following chapters:
▪ General safety precautions
▪ Preparation
DANGER: RISK OF ELECTROCUTION
Do NOT turn on the power supply (both the power supplied by the indoor unit to X3A
and the detection voltage supplied to X1A) before you have connected all the wiring
and closed the adapter.