2 | About the adapter
Installer reference guide
10
BRP069A61+BRP069A62
Daikin Altherma LAN adapter
4P464229-1E – 2023.11
2.3 System requirements
The requirements posed on the heat pump system depend on the LAN adapter
application/system layout.
App control
Item Requirement
LAN adapter software It is recommended to ALWAYS keep the
LAN adapter software up-to-date.
Smart Grid application
Item Requirement
LAN adapter software It is recommended to ALWAYS keep the
LAN adapter software up-to-date.
Domestic hot water settings To allow for energy buffering in the
domestic hot water tank, on the user
interface, make sure to set:
▪ [E-05]=1
▪ [E-06]=1
Power consumption control settings On the user interface, make sure to set:
▪ [4-08]=1
▪ [4-09]=1
INFORMATION
For instructions on how to perform a software update, see "6.4 Updating
software"[429].
2.4 On-site installation requirements
What you need on site to install the LAN adapter depends on the system layout.
BRP069A61 BRP069A62
Always
PC/laptop with Ethernet connector
Router (DHCP enabled)
At least one 2‑wire cable (for the connection of the LAN adapter to the indoor
unit (P1/P2))
Smartphone with the ONECTA app
Depending on the system layout
IF connection to an
electricity meter (X2A)
Electricity meter —
2‑wire cable —
IF connection to a solar
inverter/energy
management system
(X1A)
2‑wire cable —
Circuit breaker
(100mA~6A, typeB)
—