12 Operation
Installer and user reference guide
12
BRC1H51W+K+S
Wired remote controller
4P513689-1 – 2018.02
a
ON/OFF
When OFF, press to turn ON the system. As a result, the
status indicator (e) will turn ON too.
When ON, press to turn OFF the system. As a result, the
status indicator (e) will turn OFF too.
b
ENTER/ACTIVATE /SET
From the home screen, enter the main menu.
From the main menu, enter one of the submenus.
From their respective submenu, activate an operation/
ventilation mode.
In one of the submenus, confirm a setting.
c
CYCLE/ADJUST
Cycle left.
Adjust a setting (default: decrease).
d
CYCLE/ADJUST
Cycle right.
Adjust a setting (default: increase).
INFORMATION
The behaviour of the status indicator is according to field
settings. For more information, see "13.1.3Status indicator
settings"on page14.
12.2 Screen
Home screen
Depending on installer configuration, the controller either has a
standard or a detailed home screen. In most cases, the standard
home screen gives you only the active operation mode, messages (if
any), and the setpoint temperature (in case of Cooling, Heating, or
Auto operation mode). The detailed home screen gives you all kinds
of information through status icons.
Standard Detailed
a
b
c
19
a
b
c
a Messages
b Active operation mode
c Setpoint temperature
Home screen mode is set with remote controller field setting R1-7
(Home screen). For more information, see "Remote controller field
settings"on page18.
Backlight
The screen backlight has the following states:
State Description
ON For the controller to be operable, the screen backlight
needs to be ON (otherwise the controller does not
detect any button presses). To turn ON the backlight,
press shortly.
For instructions on how to set screen brightness and
contrast when the backlight is ON, see "13.1.2Screen
settings"on page13.
State Description
OFF
ON faintly
After a period of operation inactivity, the backlight will
either turn OFF, or go into a faint ON state, depending
on operation conditions:
Operation OFF: backlight OFF,
Operation ON: backlight ON faintly.
Backlight state changeover after inactivity is set with
remote controller field setting R1-8 (No-operation
timer). Backlight faintness is set with remote controller
field setting R1-10 (Backlight faintness). For more
information, see "Remote controller field settings"on
page18.
12.3 Status indicator
+
-
a
a Status indicator
For instructions on how to make status indicator settings, see
"13.1.3Status indicator settings"on page14.
12.4 Information
12.4.1 Information screen
The information screen collects the following information:
Information Description
Software version The information screen will
always contain the latest
software version.
a
a Software version