15
To perform error code diagnosis
1. Press and hold button for 5 seconds.
•
blinks.
2. Press
to check on the error code.
• Keep pressing on the button until a long “beep” acknowledgement heard
from the indoor unit.
To exit from error code diagnosis
3. Press and hold button for 5 seconds.
Fault Diagnosis
Note
• After connecting to wireless LAN adapter, remote controller setings prevail over WLAN apps
setting.
Notes
• A short “beep” and two consecutive “beep” acknowledgement from the indoor unit indicates a
non-correspondence error code.
• A long “beep” acknowledgement from the indoor unit indicates a correspondence error code.
• User shall not attempt to repair or modify the air conditioner as any incorrect work may result in
electric shock or fi re.
• Consult the service personnel in case the air conditioner is found to be faulty.
Error code defi nition
Error
Code
Meaning
00 Normal
A1 Malfunction of indoor unit PCB
A3 Drain level control system abnormal
A5 Antifreeze
A6 Indoor fan motor abnormal
AH Electrical air cleaner abnormal
C4 Indoor heat exchanger (1) thermistor short / open
C5 Indoor heat exchanger (2) thermistor short / open
C7 Louver limit switch error
C9 Indoor room thermistor short / open
CC Malfunction of humidity sensor system
CH -
E1 Outdoor PCB error
E3 High pressure protection
E5 Compressor motor lock / compressor overload
E6 Compressor start-up error
E7 Outdoor DC fan motor lock
E8 AC input overcurrent
EA 4 way valve error
F3 Discharge pipe overheat
F6 Abnormal high pressure
F8 -
FA Heat exchanger overheat
Error
Code
Meaning
H0 Compressor sensor system error
H3 High pressure switch error
H6 Compressor feedback detection error
H7 Malfunction of outdoor unit fan motor signal
H8 AC current sensor error
H9 Outdoor air thermistor short / open
J3
Compressor discharge pipe thermistor short /
open / misplaced
J6 Outdoor heat exchanger thermistor short / open
J8 Liquid pipe thermistor short / open
J9 Gas pipe thermistor short / open
L3 Outdoor control box overheat
L4 Heat sink overheat
L5 IPM error / IGBT error
P4 Heat sink thermistor short / open
U0 Insuffi cient gas
U2 DC voltage out of range
U3 Transmission error
U4 Communication error
UA Installation error
UF
Piping & wiring installation mismatch / wrong
wiring / insuffi cient gas
UH Antifreeze (other rooms)