Functions Description
Crowd Gathering
Detection
●
An alarm is triggered when the duration of crowd gathering in
the detection area exceeds the defined time.
●
Set the detection area as a polygon with an arbitrary shape.
●
Set the minimum duration and alarm interval. Duration: 1 s–300
s; alarm interval: 1 s–300 s.
●
Set the sensitivity from 1 to 10.
Object Detection
●
Set the detection area as a polygon with an arbitrary shape.
●
An alarm is triggered when suspicious objects are left in key
detection areas or are moved for longer than the minimum
duration time.
●
Set the minimum duration time from 6 to 3600 seconds.
Call Detection
●
Set the detection area as a polygon with an arbitrary shape.
●
An alarm is triggered when the behavior is detected to last
longer than the defined minimum duration.
●
Set the minimum duration and alarm interval. Minimum
duration: 1 s–600 s; alarm interval: 0 s–600 s.
●
Set the sensitivity from 1 to 10. It is 5 by default.
Using Mobile Phone
Detection
●
Set the detection area as a polygon with an arbitrary shape.
●
An alarm is triggered when the behavior is detected to last
longer than the defined minimum duration.
●
Set the minimum duration and alarm interval. Minimum
duration: 1 s–600 s; alarm interval: 0 s–600 s.
●
Set the sensitivity from 1 to 10. It is 5 by default.
Fall Detection
●
Set the detection area as a polygon with an arbitrary shape.
●
Detect squatting or falling. Falling and squatting are selected by
default. The check mark on falling cannot be removed.
●
Set the minimum duration and alarm interval. Minimum
duration: 1 s–600 s; alarm interval: 0 s–600 s.
●
Set the sensitivity from 1 to 10. It is 5 by default.
Running Detection
●
Set the detection area as a polygon with an arbitrary shape.
●
Set the sensitivity from 1 to 10. It is 5 by default.
Smoking Detection
●
Set the detection area as a polygon with an arbitrary shape (only
one detection area and one smoking detection rule can be
configured).
●
1U server supports 16-channel smoking detection analysis,
overlaid analysis of smoking detection and other rules.
●
An alarm is triggered when the behavior is lasted for longer than
the defined time.
●
Set the minimum duration and alarm interval. Minimum
duration: 1 s–600 s. It is 30 s by default. Alarm interval ranges
from 0 to 600 seconds. It is set as 0 by default.
●
Set the sensitivity from 1 to 10. It is 5 by default.