DGS-6604 m/ mSW Rls. 1.00.029 reboot
CLI Reference Guide
387
R
reboot
Use this command to reboot a module on the specified slot. The module can be
either a control module or a line card control module.
reboot [unit UNIT-ID ]
Default None
Command Mode. Privileged EXEC level 15
Usage Guideline This command is only available for privilege level 15 and above.
This command can be used to reboot a module in a specific slot. If no unit ID is
specified, all of the modules in the system will be rebooted.
If the CM module is specified to be reboot, then the entire system (all modules)
will reboot.
Note:
Example The following example reboots the whole system:
.
Syntax Description
UNIT-ID Specifies the unit id.
DGS-6600:15#reboot
Warning: This command will cause system reboot.
Do you want to continue (y/n) [n]?y
Save log message before reboot(y/n) [n]?y