D-Link DGS-6600-PWR handleiding

761 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 328 van 761
DGS-6604 m/ mSW Rls. 1.00.029 logging host
CLI Reference Guide
297
Command Mode Global configuration
Usage Guideline The number of supporting SYSLOG servers is project dependent. When the
number of configured SYSLOG servers reaches the maximum capacity, a new
SYSLOG server is unable to be configured before and existing entry is deleted
using the command no logging host.
The severity level limits the logging of system messages sent to Syslog servers
to only those messages at and up to the specified level. For example, if the trap
severity is debugging, all logs in the Syslog daemon are sent to the log server
host. If the level of log trap is alert, then only alert and emergency logs are sent.
The keyword facility specifies the syslog facility in the SYSLOG messages which
are sent to the server.
For the no command, if the IP address is not specified, all logging hosts will be
deleted.
Example The below example shows how to create a log server with the host address
20.3.3.3 . The command configures the server to receive logs with a severity
level set to critical
Verify the settings with the show logging host command.
Switch> enable
Switch# configure terminal
Switch(config)# logging host 20.3.3.3 severity critical

Bekijk gratis de handleiding van D-Link DGS-6600-PWR, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkD-Link
ModelDGS-6600-PWR
CategorieNiet gecategoriseerd
TaalNederlands
Grootte52758 MB

Caratteristiche Prodotto

Kleur van het productGrijs
Breedte- mm
Diepte- mm
Hoogte- mm
Geluidsniveau- dB