CYP SY-12H-4K22 handleiding
Handleiding
Je bekijkt pagina 34 van 44

34
COMMAND
Description and Parameters
SET AUTOMATION EVENT N1 CEC N2 DELAY N3 SEC
Set the delay (in seconds) to wait before triggering CEC automation
event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = A ~ B [Target output port]
N3 = 0 ~ 240 [Delay in seconds]
GET AUTOMATION EVENT N1 CEC N2 DELAY
Show the currently set delay (in seconds) to wait before triggering
CEC automation event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = A ~ B [Target output port]
Bekijk gratis de handleiding van CYP SY-12H-4K22, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | CYP |
| Model | SY-12H-4K22 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 2797 MB |







