COMMAND
Description and Parameters
SET AUTOMATION EVENT N1 CEC N2 DELAY N3 SEC
Set the delay (in seconds) to wait before triggering CEC automation
event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = A ~ B [Target output port]
N3 = 0 ~ 240 [Delay in seconds]
GET AUTOMATION EVENT N1 CEC N2 DELAY
Show the currently set delay (in seconds) to wait before triggering
CEC automation event N1.
Available values for N1:
1 [Power on]
2 [Out A sync active]
3 [Out A sync lost]
4 [Out B sync active]
5 [Out B sync lost]
N2 = A ~ B [Target output port]