COMMAND
Description and Parameters
GET IN 1 REFRESH RATE
Show the current refresh rate of the source on the Input.
GET IN 1 INTERLACE
Show the current interlace state of the source on the Input.
GET IN 1 SYNC STATUS
Show the current sync status of the source on the Input.
SET IN 1 EDID N1
Set the EDID to use with the Input.
Available values for N1:
1 [FHD 2CH]
2 [FHD MCH]
3 [UHD 2CH]
4 [UHD MCH]
5 [UHD+ 2CH]
6 [UHD+ MCH]
7 [User 1]
8 [Sink A]
9 [Sink B]
GET IN 1 EDID
Show the currently selected EDID used by the Input.
GET EDID LIST
List all available EDID selections.
SET USER 1 EDID DATA N1
Upload a new User EDID in HEX format.
N1 = {EDID data in hh,hh,hh,hh,... HEX pair format}
GET USER 1 EDID DATA
Show the Current User EDID as HEX data.