34
COMMAND
Description and Parameters
set automation event N1 uart A endchar N2
Set the termination character(s) to attach after the specified
command in the command pool.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
Available values for N2:
0 [None]
1 [CR]
2 [LF]
3 [CR+LF]
get automation event N1 uart A endchar
Show the current termination character(s) used by the specified
command in the command pool.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
set uart 2 baudrate
Set the baud rate of the Bypass RS-232 port.
Available values for N1:
4800 [4800 baud]
7200 [7200 baud]
9600 [9600 baud]
14400 [14400 baud]
19200 [19200 baud]
38400 [38400 baud]
57600 [57600 baud]
115200 [115200 baud]