COMMAND
Description and Parameters
set automation event N1 cec A N2
Enable or disable the specified Automation Event’s CEC response.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
Available values for N2:
ON [Event CEC response enabled]
OFF [Event CEC response disabled]
get automation event N1 cec A
Show the current state of the specified Automation Event’s CEC
response.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
set automation event N1 cec A delay N2
Set the delay time that the specified Automation Event must
continue to be true before sending the defined CEC command.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
N2 = 0~240 [Delay time in seconds]