COMMAND
Description and Parameters
set uart 1 data bit N1
Set the data bits for the unit’s internal RS-232 port.
Available values for N1:
5 [5 data bits]
6 [6 data bits]
7 [7 data bits]
8 [8 data bits]
get uart 1 data bit
Show the current number of data bits of the unit’s internal RS-232
port.
set uart 1 parity N1
Set the parity of the unit’s internal RS-232 port.
Available values for N1:
0 [None]
1 [Odd]
2 [Even]
get uart 1 parity
Show the current parity setting of the unit’s internal RS-232 port.
set ip mode N1
Set the unit’s IP address assignment mode.
Available values for N1:
0 [Static IP]
1 [DHCP]
get ip mode
Show the current IP address assignment mode.
get ipcong
Show the unit’s current IP conguration information.