8. Collaboration Receiver Commands**
COMMAND DESCRIPTION AND PARAMETERS
GET OUT N1 TIMING
Show the current output timing for Rx
Output N1.
N1 = B [HDMI Out on the Rx]
SET OUT N1 COLOUR SPACE N2
Set Rx Output N1’s colour space.
N1 = B [HDMI Out on the Rx]
Available values for N2:
0 [Bypass]
1 [RGB]
2 [YUV 4:4:4]
3 [YUV 4:2:2]
4 [YUV 4:2:0]
5 [Auto Detect]
Note: Selecting the 4:2:2 or 4:2:0 colour
space might result in incorrect colours if
the connected display does not support the
combination of colour space and output
timing.
GET OUT N1 COLOUR SPACE
Show Rx Output N1’s colour space.
N1 = B [HDMI Out on the Rx]
SET OUT N1 COLOUR DEPTH N2
Set Rx Output N1’s colour bit depth.
N1 = B [HDMI Out on the Rx]
Available values for N2:
0 [Bypass]
1 [8bit]
2 [10bit]
3 [12bit]
4 [16-bit]
5 [Auto Detect]
Note: Outputting YUV 4:2:2 at bit depths
above 8-bit might result in incorrect colour.
GET OUT N1 COLOUR DEPTH
Show Rx Output N1’s colour bit depth.
N1 = B [HDMI Out on the Rx]