42
6. Banner Commands
COMMAND DESCRIPTION AND PARAMETERS
SET OUT N1 BANNER N2
Enable or disable Output N1’s banner.
N1 = A ~ B [Output letter]
Available values for N2:
OFF [Banner disabled]
ON [Banner enabled]
GET OUT N1 BANNER
Show Output N1’s banner enable state.
N1 = A ~ B [Output letter]
SET OUT N1 BANNER MODE N2
Set the banner text display mode.
N1 = A ~ B [Output letter]
Available values for N2:
1 [Show Input timing &
time]
2 [Show user text]
GET OUT N1 BANNER MODE
Show the banner text display mode.
N1 = A ~ B [Output letter]
SET OUT N1 BANNER TEXT N2
Set the user banner text string.
N1 = A ~ B [Output letter]
N2 = {Text} [Banner text (64 char
max)]
GET OUT N1 BANNER TEXT
Show the current user banner text for
Output N1.
N1 = A ~ B [Output letter]