COMMAND
Description and Parameters
set automation event N1 uart wait N2 sec
Set the length of time to wait after an Automation Event's RS-232
response has been activated before ANY other Automation Event
can be detected.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
N2 = 1 ~ 300 [Wait time in seconds]
Note: If both an RS-232 and CEC event is activated by the same
Automation Event, the longer of the 2 wait times will be used.
get automation event N1 uart wait
Show the wait time for the specified Automation Event's RS-232
response.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
set automation event N1 uart command N2
Set the RS-232 command string to send when the specified
Automation Event is activated.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
N2 = {Command} [Max 32 characters]