COMMAND DESCRIPTION AND PARAMETERS
set automation event
N1 cec A wait N2
Set the length of time to wait after an
Automation Event's CEC response has been
activated before ANY other Automation
Event can be detected.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
N2 = 0 ~ 240 [Wait time in seconds]
get automation event
N1 cec A wait
Show the wait time for the specified
Automation Event's CEC response.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
set automation event
N1 cec A command N2
Set the CEC command to send when the
specified Automation Event is activated.
Available values for N1:
1 [Power on]
2 [Out A source active]
3 [Out A source lost]
N2 = {CEC data} [Comma delimited hex
pairs]