COMMAND DESCRIPTION
P1 Power On
P2 Power O all
P? Report power status
PRESET Save M Save current A/V routing. M=1~8.
PRESET Load M Recall current A/V routing. M=1~8.
PRESET Show [M] List current stored A/V preset.
M=1~8.
If M is omitted, list all A/V preset.
PRESET name M=”NameString” Set verbose name of specied
preset slot M. Maximum 32
characters.
EDID All=EdidSetNumber Set EDID of all input port
=Specied EDID set number. If
EdidSetNumer=”O”, it becomes
independent mode.
EDID HDMI_In M=EdidSetNumber Set specied HDMI input port
M=Specied EDID set number.
EDID M Name=”NameString” Set verbose name of specied EDID
slot M.
FactoryDefault
(Hidden Command)
Reset all conguration to factory
default.
MAC Show MAC address.
? Display all available commands
(Except hidden commands)
Help Display all available commands
(Except hidden commands)
Ver Show rmware version