22
COMMAND
Description and Parameters
get telnet login
Show the current state of the Telnet login requirement.
Note: Only available via RS-232.
set webgui login timeout N1
Set the WebGUI inactivity timeout value.
Available values for N1:
0 [No timeout]
1~240 [Timeout in minutes]
get webgui login timeout
Show the current WebGUI inactivity timeout value.
set in N1 name N2
Set the name of the specied input.
Available values for N1:
1 [HDMI input 1]
2 [HDMI input 2]
3 [HDMI input 3]
4 [HDMI input 4]
N2 = {Name} [ASCII, 32 characters max]
get in N1 name
Show the current name of the specied input.
Available values for N1:
1 [HDMI input 1]
2 [HDMI input 2]
3 [HDMI input 3]
4 [HDMI input 4]