66
COMMAND
Description and Parameters
get audio out N1 name
Show the current name for the specied output’s audio.
N1 = A~B [Output port]
set all in edid mode N1
Select the EDID management mode to use (All or Appoint) for all
inputs.
Available values for N1:
ON [All mode]
OFF [Appoint mode]
get all in edid mode
Show the current EDID management mode used by all inputs.
set all in edid N1
Set the EDID to use when the “All” EDID mode is active.
Available values for N1:
1 [1080p@60Hz, 2 channel audio]
2 [4K@30Hz, 2 channel audio]
3 [4K@60Hz, 2 channel audio]
7 [User 1]
8 [User 2]
9 [User 3]
10 [User 4]
15 [Sink A]
16 [Sink B]
get all in edid
Show the current EDID used by the “All” EDID mode.