COMMAND
Description and Parameters
set audio out N1 mute N2
Enable or disable muting the specied audio output.
N1 = A~B [Output port]
Available values for N2:
ON [Mute]
OFF [Unmute]
get audio out N1 mute
Show the current mute state of the specied output.
N1 = A~B [Output port]
set audio out N1 route N2
Route the specied audio source to the specied audio output.
N1 = A~B [Output port]
Available values for N2:
1 [Input 1]
2 [Input 2]
3 [Input 3]
4 [Window 1]
5 [Window 2]
6 [Window 3]
get audio out N1 route
Show the current audio source routed to the specied audio
output.
N1 = A~B [Output port]
set audio out N1 name N2
Set the name for the specied output’s audio.
N1 = A~B [Output port]
N2 = {Name} [Audio output name]