54
COMMAND
Description and Parameters
set window N1 position area N2,N3,N4,N5
Set the upper left corner position and size of the specied
window all within a single command.
N1 = 1~3 [Window number]
N2 = 0~{Max res} [Horizontal position]
N3 = 0~{Max res} [Vertical position]
N4 = 0~{Max res} [Horizontal size]
N5 = 0~{Max res} [Vertical size]
Note: Valid in multi-windowing modes only.
get window N1 position area
Show the current upper left corner position, and window size of
the specied window.
N1 = 1~3 [Window number]
Note: Valid in multi-windowing modes only.
set window N1 hposition N2
Set the horizontal position of the specied window.
N1 = 1~3 [Window number]
N2 = 0~{Max res} [Horizontal position]
Note: Valid in multi-windowing modes only.
get window N1 hposition
Show the current horizontal position of the specied window.
N1 = 1~3 [Window number]
Note: Valid in multi-windowing modes only.