14
To make changes to the unit you are currently connected to, select This”
as the target. Otherwise, select the IP address of the receiver (client) you
want to apply changes to from the Apply To:” drop down.
Note: While it is possible to create small video walls using unicast mode, in
order to more efficiently use the available network bandwidth, it is strongly
recommended to only use multicast mode when creating video walls.
1) Bezel and Gap Compensation: This section of the Video Wall tab
is used to define the physical dimensions of each display being
used in the video wall. Accurate measurements are needed of the
monitor’s outer frame (OW, OH) and the video screen (VW, VH). The
measurements may be made using any unit format (inches, mm, cm,
etc.) as long as ALL measurements in the same wall are made using
the exact same units and the numbers are integers.
OW (Outer Width): This is the horizontal measurement of the
display’s outer case.
OH (Outer Height): This is the vertical measurement of the
display’s outer case.
VW (Video Width): This is the horizontal measurement of the
display’s video screen.
VH (Video Height): This is the vertical measurement of the display’s
video screen.
Note: Typically all monitors in a video wall are identical and have the
same dimensions, but it is possible to use differently sized displays as
long as the same measurement units are used to measure each display
and the displays are still arranged in a normal rectangular layout with
corners meeting at the same place.