4. Transmitter Specific
COMMAND DESCRIPTION AND PARAMETERS
SET_VW_LAYOUT N1 N2 {N3} Set the video wall’s total horizontal and
vertical display count.
N1 = 1~16 [Horizontal display
count]
N2 = 1~16 [Vertical display
count]
N3 = 0~255 [Target Rx {Optional}]
Note: Target Receiver number can be obtained
by turning on the Video Wall OSD. Omitting
N2 makes the setting global to all Receivers.
SET_VW_POS N1 N2 {N3} Set the display’s position within the video
wall. (Cannot exceed the video wall’s
horizontal and vertical display count.)
N1 = 0~15 [Row]
N2 = 0~15 [Column]
N3 = 0~255 [Target Rx {Optional}]
Note: Target Receiver number can be obtained
by turning on the Video Wall OSD. Omitting
N2 makes the setting global to all Receivers.
SET_VW_BC N1 N2 N3 N4 {N5} Set the video wall display’s bezel
compensation values.
N1 = 0~99999 [Video width]
N2 = 0~99999 [Total display width]
N3 = 0~99999 [Video height]
N4 = 0~99999 [Total display height]
N5 = 0~255 [Target Rx {Optional}]
Note: Target Receiver number can be obtained
by turning on the Video Wall OSD. Omitting
N2 makes the setting global to all Receivers.