CYP IP-7000H-TX handleiding
Handleiding
Je bekijkt pagina 14 van 48

9
WebGUI Overview
All major functions of the unit, including status, streaming method,
streaming channel selection, output resolution, video wall conguration,
EDID management, Ethernet settings, and reset/rmware functions
are controllable via multiple tabs in the WebGUI interface allowing for
reasonably intuitive operation.
Each transmitter, receiver, or transceiver is controlled by its own WebGUI
interface which may be accessed by opening a standard web browser
on a PC and typing in the IP address of the unit you wish to connect to.
On a transceiver unit, the IP address of a unit can be obtained simply
by checking the information screen within the OSD menu, accessed by
pressing the menu button.
On stand-alone transmitters/receivers you can discover the IP address
by checking the status OSD that is displayed when there is no live video
source or no live link. Breaking the link is accomplished by pressing and
holding the “LINK” button on the front of the unit for 3 seconds (The
LINK light will blink rapidly, then turn o). Once the link is broken, each
connected receiver will output a 640×480 black screen with OSD text
at the bottom identifying its own IP address (Local IP), as well as the IP
address of the transmitter (Remote IP) that shares the same broadcasting
channel with it (channel 0 by default). After obtaining the IP address
information, press and hold the “LINK” button again for 3 seconds to
return the unit to normal operation (The LINK light will light up solid
yellow).
After connecting to a unit’s WebGUI, you will nd a screen containing
multiple tabs for each functionality area of the unit. The individual tabs
and functions will be introduced in the following sections.
Note: AVoIP streaming uses a large amount of bandwidth (especially at higher
resolutions) and a Gigabit Ethernet network switch with jumbo frame support
and IGMP snooping is required. A professional managed switch with VLAN
support is strongly recommended. Please note that most consumer-grade
routers are not able to handle the high traffic rates generated by multicast
mode, so using a router directly as your network switch is discouraged. It is
strongly suggested to avoid mixing your regular network traffic with AVoIP
streaming traffic and the AVoIP traffic should exist within a separate subnet,
at the minimum.