26
COMMAND
Description and Parameters
get_frame_rate
Show the unit’s current frame rate setting.
set_vw_osd N1 {N2}
Enable/disable video wall OSD to display the Target Receiver number on the
designated display.
Available values for N1:
0 [Disable]
1 [Enable]
N2 = 0~255 [Target Rx {Optional}]
Note: Target receiver number can be obtained by turning on the Video Wall OSD.
Omitting N2 makes the setting global to all receivers.
set_vw_layout N1 N2 {N3}
Set the video wall’s total horizontal and vertical display count.
N1 = 1~16 [Horizontal display count]
N2 = 1~16 [Vertical display count]
N3 = 0~255 [Target Rx {Optional}]
Note: Target receiver number can be obtained by turning on the Video Wall OSD.
Omitting N3 makes the settings global to all receivers.
set_vw_pos N1 N2 {N3}
Set the display’s position within the video wall. (Cannot exceed the video
wall’s horizontal and vertical display count.)
N1 = 0~15 [Row]
N2 = 0~15 [Column]
N3 = 0~255 [Target Rx {Optional}]
Note: Target receiver number can be obtained by turning on the Video Wall OSD.
Omitting N3 makes the settings global to all receivers.