15
6.6.3 Video Commands
COMMAND
DESCRIPTION VARIABLES
SET IN N1 NAME N2
Set the name for input N1. N1 = 1~4 [Input number]
N2 = {name} [24 characters max]
GET IN N1 NAME
Show the name of input N1. N1 = 1~4 [Input number]
SET OUT N1 NAME N2
Set the name for output N1. N1 = A~B [Output letter]
N2 = {name} [24 characters max]
GET OUT N1 NAME
Show the name of output N1. N1 = A~B [Output letter]
SET OUT N1 ROUTE N2
Set the routing source for output N1
and switch to matrix mode.
N1 = A~B [Output letter]
N2 = 1~4 [Input number]
GET OUT N1 ROUTE
Show the matrix mode routing source
for output N1.
N1 = A~B [Output letter]
SET PRESET 1 SAVE
Save the current video layout as a
preset.
SET PRESET 1 LOAD
Load the saved video layout preset.