1) EDID Mode: Select how to assign EDIDs to the unit’s inputs. Selecting
“Independent allows for a dierent EDID to be assigned to each input,
selecting All” allows for a single EDID to be assigned to all inputs.
2) All EDID: Select the EDID to assign to all inputs.
Note: Only available in the “All” EDID Mode.
3) In 1~2 EDID: Select the EDID to assign to the specied input.
Note: Only available in the “Independent” EDID Mode.
4) User 1~4 Update: To update any of the units 4 User EDIDs via USB,
select Yes” next to the appropriate User EDID and then insert a USB
stick containing the new EDID into the Service port. The upload will
occur immediately.
Note: The USB stick must contain, in the root directory, a compatible and
properly named (EDID_USER_*.BIN) EDID le.
5) User 1~4 EDID Name: Display the currently set names for each User
EDID.
HDCP MODE
2ND LEVEL 3RD LEVEL
In 1 HDCP Support O
Refer to Source
REFER TO DISPLAY
In 2 HDCP Support O
Refer to Source
REFER TO DISPLAY
-HDCP Status-
Out
[Current HDCP Status]Win 1
Win 2
1) In 1~2: Select the HDCP behavior for each input.
HDCP Support O: Completely disables support for HDCP on that
input.