COMMAND DESCRIPTION
KEY_PRESS N HOLD Set key press macro activation
method to "Hold". (Macro activates
when key is pressed. Macro will
repeat as long as the key is held
down.)
N=1~15 (Key Number)
MACRO RUN N Run the specied macro.
N=1~30 (Macro ID)
MACRO STOP Stop all currently running macros.
MACRO STOP N Stop the specied macro.
N=1~30 (Macro ID)
DEVICE ADD N N1 N2 N3 Add Telnet device denition to slot
N.
N=1~16 (Device Slot Number)
N1=X.X.X.X (IP Address, X=0~255)
N2=0~65535 (Port)
N3={Name} (Up to 24 characters,
no spaces)
DEVICE DELETE N Delete Telnet device denition in
slot N.
N=1~16 (Device Slot Number)
DEVICE N N1 Enable/Disable dened Telnet
device.
N=ENABLE, DISABLE
N1=1~16 (Device Slot Number)
Note: Commands will not be executed unless followed by a carriage return.