Macro 4 (BLUE LED OFF): Switch o all blue LEDs. (Set brightness
to 0%).
■
Macro 5 (LED DEMO MODE): LED Demo Mode toggle. (Switch
Demo Mode on/o).
■
Macro 6 (LED/RLY DEMO): Light the blue LEDs with 10%
brightness
→
set all blue LEDs to 0% brightness
→
close then
open Relay 1 followed by Relay 2 (UK 2-gang only) with a delay of
1000ms between commands.
2) Background Light: This slider allows the user to adjust the overall
maximum brightness of the keypad’s LEDs. This setting denes the
brightness level when an LED is set to “100%”.
3) Demo Mode: This switch enables or disables the LED Demo Mode.
When Demo Mode is active, the unit will automatically turn the LEDs
on and o in various patterns.
Note: LED Demo Mode is on by default. Pressing a physical button on the
unit will temporarily pause Demo Mode so that normal macros may be
executed. Demo Mode will automatically resume after 1 minute of idle
time.
4) Macro Edit: Click on any button’s edit icon (
) to edit that button’s
macro. The Macro Edit window displays the full contents of the macro
including it’s name as well as each command’s communication
interface to use with its associated parameters, delay time
before executing the next command, and conditional execution
requirements. The order of command execution is from top to bottom.
When you have nished editing the macro click on “Save Change”.